Search SRF:
sidebar

Existing JLab SRF Capabilities

Experience

Efforts that Jefferson Lab’s SRF capabilities have been or are being used for include:

  • Design, construction, testing, and operating experience for the 47 operational cryomodules (containing 358 cavities) in CEBAF and in the energy-recovering linear accelerator that drives the Jefferson Lab free-electron laser.

(CW, E pk = 14–30 MV/m)

  • Design, prototyping, assembly, and testing of Spallation Neutron Source cavities and cryomodules (23).

(Pulsed, E pk = 25–35 MV/m)

  • Currently completing a second-generation prototype cryomodule for CEBAF’s 12 GeV upgrade.

(CW, E pk = 40–55 MV/m, high Q 0 )

  • Numerous collaborative R&D cavity tests.

(CW, E pk £ 80 MV/m, variety of frequencies and shapes, fabrication and processing techniques)

Next --›