sidebar
|
|
Existing JLab SRF Capabilities
Experience
Efforts that Jefferson Lab’s SRF capabilities have
been or are being used for include:
- Design, construction, testing, and operating experience for the
47 operational cryomodules (containing 358 cavities) in CEBAF and
in the energy-recovering linear accelerator that drives the Jefferson
Lab free-electron laser.
(CW, E pk = 14–30 MV/m)
- Design, prototyping, assembly, and testing of Spallation Neutron
Source cavities and cryomodules (23).
(Pulsed, E pk = 25–35 MV/m)
- Currently completing a second-generation prototype cryomodule
for CEBAF’s 12 GeV upgrade.
(CW, E pk = 40–55 MV/m, high Q 0
)
- Numerous collaborative R&D cavity tests.
(CW, E pk £ 80 MV/m, variety of frequencies
and shapes, fabrication and processing techniques)
|